Dubai, United Arab Emirates
+919359902383
+919359902383

APPA Ophthalmic Ultrasound Scanner MARVEL II (A-B Scan with UBM) | ErnestVision USA

update image

Ophthalmic Ultrasound Scanner – Model MARVEL II (A-B Scan with UBM)

Fast Delivery β€’ Latest Price β€’ Global Export

Powered by Ernest Pharmaceutical Group

(All brands under Ernest Pharmaceutical Pvt. Ltd.)

@ERNESTVISION | ERNEST PHARMACEUTICAL PVT. LTD.

For global exports, OEM branding & distributor partnerships
πŸ“§ Emailexports@ernestpharmaceuticals.com
🌐 Websites:

πŸ“ž International Sales Contact
Sachin Kashiwar
πŸ“² WhatsApp: +91 93599 02383
πŸ”— https://wa.me/919359902383


The MARVEL II Ophthalmic Ultrasound Scanner is an advanced, all-in-one diagnostic imaging system integrating A-Scan, B-Scan, and Ultrasound Biomicroscopy (UBM) on a single platform.
It is designed for comprehensive anterior and posterior segment evaluation, making it an ideal solution for modern ophthalmic diagnostics.

MARVEL II is widely used by ophthalmologists, eye hospitals, diagnostic centers, and teaching institutions for accurate biometry, high-resolution ocular imaging, and advanced anterior segment assessment.

Key Features

  • Triple Modality System: A-Scan + B-Scan + UBM in one integrated unit

  • High-Resolution Imaging for precise ocular diagnostics

  • High-Frequency UBM Capability for detailed anterior segment visualization

  • Accurate Biometry for reliable IOL power calculation

  • Real-Time Imaging with fast processing speed

  • User-Friendly Interface with auto & manual measurement modes

  • Compact & Portable Design, suitable for clinics and hospitals

TECHNICAL SPECIFICATION

Ophthalmic Ultrasound Scanner – MARVEL II (A-Scan | B-Scan with UBM)


A-Scan Specification
ParameterSpecification
A-Scan Frequency10 MHz with Fixation Light
Scan ModeManual & Auto
Scan MethodContact & Immersion
Gain Control0% – 100%
IOL FormulasSRK II, SRK-T, Holladay 1, Binkhorst II, Haigis (Hoffer Q – Price on Request)
Refraction FormulasClinical History Method, Contact Lens Method, Rosa, SRK-T, Shammas
Lens Types Supported               Aphakic, Dense Cataract, Phakic, Pseudophakic (Acrylic, PMMA, Silicone), Silicone Oil
Axial Length Measurement12 – 40 mm
IOL ConfigurationMore than 200
Patient Record FieldsName, MRD, Gender, DOB, Doctor’s Comments
Printer SupportAny PC-supported standard printer (Laser, DeskJet, Inkjet)
Data Export FormatsJPEG, PDF, HTML, RTF, XLS, XLSX, CSV, TXT, TIFF
Patient Record StorageInternal Hard Disk – 1 TB

B-Scan Specification
ParameterSpecification
B-Scan Probe Frequency12 MHz (Optional: 10 MHz, 20 MHz)
Gain Range–128 to +128
TGC ControlNear, Mid, Far (User-adjustable slider)
Scan Angle20Β° – 60Β°
View Zone30 – 60 mm
Vector Density256 vectors Γ— 2048 points per vector
Database Image Size                       1 MB per image
Gray Scale256 levels
Image Capture Rate15 fps

UBM Specification
ParameterSpecification
UBM Probe Frequency35 MHz (Optional: 50 MHz)
Scan Angle20Β° – 35Β°
View Zone                             15 – 18 mm
Imaging ApplicationAnterior Segment, Angle, Iris, Ciliary Body

Measurement & Annotation Tools
FeatureDetails
Measurement ToolsAngle, Caliper, Area
Annotation Tools                  Arrow Mark, Probe Orientation, Text Annotation
A/B Scan CapabilityA-Scan vector overlay on B-mode images
Velocity AdjustmentAdjustable to tissue/material

Image & Video Processing
ParameterSpecification
False Color (Flood Fill)Image segment differentiation
Video Recording                          AVI format, Cine Loop
Image Buffer600 frames per cine (Total: 6000 frames)

Export Formats

Format                        PNG, JPEG, BMP, GIF, TIFF
Format                        JPEG, PDF, HTML, MHT, RTF, XLS, XLSX, CSV, TXT, Image

System Control & Input Devices

DeviceSupport
KeyboardUSB
Mouse                           USB
Foot PedalSupported


Clinical Applications

  • Axial length measurement for IOL calculation

  • Evaluation of retina, vitreous, choroid, and optic nerve

  • Diagnosis of dense cataract and media opacities

  • Anterior segment imaging (angle, iris, ciliary body) using UBM

  • Glaucoma assessment and pre-/post-operative evaluation


Ideal For

  • Eye hospitals & ophthalmic clinics

  • Diagnostic & imaging centers

  • Teaching hospitals & research institutes

  • Global distributors, resellers & OEM buyers


Why Choose MARVEL II?

  • Complete all-in-one ultrasound solution

  • High diagnostic accuracy with clinical confidence

  • Cost-effective alternative to multiple standalone systems

  • Designed for global export and long-term clinical use


Why Choose Ernest Pharmaceutical Pvt. Ltd.?

πŸ’  ISO-Certified Global Exporter
πŸ’  10+ Years of International Healthcare Export Experience
πŸ’  Private Label & OEM Manufacturing Support
πŸ’  Complete Regulatory Documentation
    (COA, COPP, COO, MSDS, etc.)
πŸ’  Temperature-Controlled International Logistics via

    DHL, FedEx & Aramex


Payment & Logistics

πŸ’± Accepted Payment Modes

  • Telegraphic Transfer (TT)

  • International Bank Transfer

πŸ“¦ Secure global packaging & export-compliant documentation


Contact for Bulk Orders & Price Quotations

Ernest Pharmaceutical Pvt. Ltd.
πŸ“§ Emailexports@ernestpharmaceuticals.com

 2025-12-23T05:50:40