Dubai
+919405476170
+919359902383

Products

6814772a5d263414004dd4a4 Card 2

product image
EYE DROPS

Product introduction Hynidase Injection is used as a preservative in combination with other medicines. It enhances the absorption and spread of fluids for hydration, improves the dispersion and effectiveness of injected drugs, and improves the absorption of contrast agents used in certain imaging tests, like subcutaneous urography. Generally, Hynidase Injection comes in combination with injectable medicines. It must be administered as per prescription under the supervision of a doctor or a nurse. Let your doctor know if you have any known allergies to this medication. Hynidase Injection is a safe medicine and has minimal or no side effects. However, some patients might experience injection site reactions such as redness, swelling, and pain. Let your doctor know if they bother you. Marketer Shreya Life Sciences Pvt Ltd SALT COMPOSITION Hyaluronidase (1500IU) Storage Store below 30°C Uses of Hynidase Injection Preservative Benefits of Hynidase Injection In Preservative Hynidase Injection is used as a preservative to prevent damage to the original form of the medicine that is given as an injection by a doctor or nurse. If it is not present, harmful organisms can contaminate the solution and cause infections or reactions in the person who takes any such medicine. It also acts as a solvent for certain medicines and helps in better absorption of the medicine in our body.

6814772a5d263414004dd4a4 Card 2

product image
EYE DROPS

Product introduction Careprost Eye Drop is a medicine used to reduce pressure in the eyes in adults with glaucoma and high pressure in the eye. If the pressure in your eye is too high it can damage your sight, potentially leading to blindness. It works by helping fluid flow from inside the eye into the blood. Careprost Eye Drop is suitable for adults and children and can be used by itself or in combination with other eye medicines to reduce pressure. Follow the instructions given by your doctor and use this medicine regularly to get the most benefit. If you stop using it, pressure in the eye could increase and damage your sight. Never use a bottle if the seal is broken before you use it for the first time. Make sure you remove contact lenses if you wear them and wait for at least 15 minutes before putting them back. The most common side effects of this medicine include conjunctival hyperemia and eye itching. If you get any side effects, talk to your doctor. They may be able to tell you ways of reducing or preventing some side effects or suggest another treatment. If your vision is blurred or you have other changes in sight for a time, do not drive until your vision is clear. This is usually a short term side effect. Uses of Careprost Ophthalmic Solution Glaucoma Ocular hypertension Marketer Sun Pharmaceutical Industries Ltd SALT COMPOSITION Bimatoprost (0.03% w/v) Storage Store below 25°C

6814772a5d263414004dd4a4 Card 2

product image
EYE DROPS

Product introduction C-Nac Eye Drop is a prescription medicine used to treat symptoms of dry eyes. It lubricates the eyes helps in maintaining the moisture of the eyes. This way it provides temporary relief from burning and discomfort caused by dry eyes. It also reduces redness and swelling of the eye. C-Nac Eye Drop is to be used only in the affected eye. Use it in the dose and duration as advised by the doctor. Read the label carefully for instruction before you use the medicine. Wash your hands before using this medicine. Do not use too much or too little. Use it in the exact dose as prescribed by the doctor or as instructed in the label. Use of this medicine may cause application site reactions such as burning sensation, itching, irritation, and redness. However, these are usually temporary and resolve by themselves. In case of accidental contact with your ears, nose, or mouth, immediately rinse it with water. Inform your doctor if you have a known allergy to any of the ingredients in this medicine or if you are taking any other medication. It is advised not to drive or operate heavy machinery immediately after using this medicine as it may cause temporary blurring of vision and may affect your ability to drive. In Treatment of Dry eyes Dry eyes is a condition in which your eyes do not produce enough tears to keep them moist. It can be caused by sitting in front of the computer for a long time, certain medications or environmental conditions. C-Nac Eye Drop adds moisture to your eyes and keeps them lubricated. This gives relief from burning sensation and discomfort due to dryness of the eyes. C-Nac Eye Drop also reduces infection and irritation in the eye. If you wear soft contact lenses, you should remove them before applying C-Nac Eye Drop. Marketer Intas Pharmaceuticals Ltd SALT COMPOSITION Carboxymethylcellulose (3mg/ml) + Glycerin (10mg/ml) + n-acetylcarnosine (10mg/ml) Storage Store below 30°C Preservative Oxychloro Complex

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

The Volk VistaView product package includes: Volk VistaView camera Silicone eye cup for patient comfort and added stabilization during alignment Lens cap for extra protection Volk VistaView instructions for use Volk VistaView Quick Start Guide Charger International plug adapters USB-C cable Volk VistaView case for convenience when on the go Wide Field of View for Uncompromised Image Quality VistaView offers you the widest field of view in its class with 55˚ field in a single capture and even more with dynamic imaging. Just Say the Word! Voice Activated Capture for Ease of Image Capture Introducing voice-activated capture for scenarios where you need a little extra assistance such as ICUs. Quickly and easily capture images without even lifting a finger, maximizing imaging stability to get the perfect picture. Adjustable Illumination Levels for Enhanced Patient Comfort Successfully image patients from all populations, including darker retinas while maintaining patient comfort with user-adjustable illumination levels. Ideal for accommodating photophobic patients. Instantly Generate Reports for Billing, Referrals and Patient Education Add red-free filters, make notes on your findings, review patient history, and consolidate into a password-protected report ready share anytime. A great tool for resident consultations and learning, patient education, billing, and filing patient data. Specifications VOICE-ACTIVATED IMAGE CAPTURE for when you need an extra hand! RED-FREE FILTER to help enhance vascular visualization USB-C CHARGING - no external batteries needed! WIRED EXPORT TO PC VIA USB-C - just drag and drop your files to your computer INSTANT REPORT GENERATION WITH CASE NOTES so you can see your next patient sooner DICOM FILE EXPORT to easily connect your patient images to your EMR PASSWORD PROTECTED DATA EXPORT to provide a layer of protection during data sharing ON-BOARD PATIENT DATA SEARCH AND SORTING - all your patient data in one place AUTOFOCUS & MANUAL FOCUS WITH -15D TO +15D ADJUSTMENT - choose your level of control ILLUMINATION ADJUSTMENT TO HIGH, MEDIUM OR LOW SETTINGS - comfort for your patients MYDRIATIC FUNDUS CAMERA LIGHT SOURCE White LED Light STORAGE 64 GB RESOLUTION 3072 x 2122 pixels EXTERNAL DIMENSIONS 78 x 185 x 102 mm WEIGHT 500 grams WARRANTY 1 year

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Description Ideal for Viewing Anterior Chamber Angle The G-4 Gonio Lens gives the most comprehensive view of the trabecular meshwork with minimal lens rotation with its four mirror, all-glass design. This Sussman style lens features unbeatable optics for high detail examination of the angle structures. Choose from our large (28.5 mm) or small ring (25.5 mm), 2-position handle (right/left handed), Posner-style models, or opt for our no flange model for dynamic and indentation gonioscopy. We also offer a flanged version for enhanced stability during laser trabeculoplasty. 4 x 64° mirror angles 1.0x image magnification 1.0x laser spot size 15 mm (flange) / 8.4 mm (no flange) contact diameter Allows for a quick exam with maximum patient comfort No Flange/No Fluid version is ideal for dynamic and indentation/compression gonioscopy Not recommended for SLT – we recommend the Volk Rapid SLT or SLT lens instead

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Laser Capsulotomy Procedures See your patient’s posterior lens capsule in the clearest, most magnified view with our Capsulotomy Lens. Its superior optical design provides precise and safe laser application when clearing opacified lenticular tissue for post-cataract/secondary cataract Laser Capsulotomy Procedures. Experience excellent maneuverability with its short lens body, which allows more clearance between the laser and the patient’s eye. 1.57x image magnification 0.64x laser spot magnification Superior optical design provides tight focus to minimize pitting and damaging the IOL Laser Window creates a protective barrier to keep internal imaging components safe Part Number: VCAPS

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Indirect Viewing and Treatment of Peripheral Retinal Disorders The Mini Quad® XL Lens offers the clearest image of the entire retina including the ora serrata. This lens offers an impressive wide field of view, making it ideal for use in Indirect Viewing and Treatment of Peripheral Retinal Disorders including retinal detachments or giant retinal tears. You can choose from standard or self-stabilizing contact (SSV®) options to suit your needs. 112° / 134° field of view 0.39x image magnification Available in standard and self-stabilizing contact (SSV®) options for best ergonomics Ideal for retinal detachments, retinal tears, PDR, including diabetic cases requiring endolaser to the periphery Wide field of view of the entire retina including the ora serrata Part Number: VMQXLVIT (Standard) and VMQXLVITSSV (with self stabilizing contact)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Viewing Anterior Chamber Angle The G-4 Mirror Gonio Lens gives the most comprehensive view of the trabecular meshwork with minimal lens rotation with its four mirror, all-glass design. This Sussman style lens features unbeatable optics for high detail examination of the angle structures. Choose from our large (28.5 mm) or small ring (25.5 mm), 2-position handle (right/left handed), Posner-style models, or opt for our no flange model for dynamic and indentation gonioscopy. We also offer a flanged version for enhanced stability during laser trabeculoplasty. 4 x 64° mirror angles 1.0x image magnification 1.0x laser spot size 15 mm (flange) / 8.4 mm (no flange) contact diameter Allows for a quick exam with maximum patient comfort No Flange/No Fluid version is ideal for dynamic and indentation/compression gonioscopy Not recommended for SLT - we recommend the Volk Rapid SLT or SLT lens instead Part Number: VG4 (Flange, Large Ring) VG4LNF (No Flange, Large Ring) VG4SNF (No Flange, Small Ring) VG4HAN2 (No Flange, 2-in-1 Handle - Posner style)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Anterior, Peripheral and Equatorial Viewing The G-3 Gonio Lens’ three mirror, all glass design gives you the clearest, most detailed view of the iridocorneal angle, retina from equator to ora serrata and mid-peripheral/peripheral retina. With unbeatable Volk optics quality and two formats - flanged for laser trabeculoplasty and no flanged for routine gonioscopy - this Goldman-style lens is the perfect tool for Glaucoma specialists. 60° / 66° / 76° mirror angles 1.06x (flange) / 1.03x (no flange) / 1.0 (mini, no flange) image magnification 0.94x (flange) / 0.97x (no flange) / 1.0x (mini, no flange) laser spot size 15 mm (flange) / 11.4 mm (no flange) / 9.6 mm (mini, no flange) contact diameter 60˚ mirror provides a view of the iridocorneal angle, 66˚ mirror provides a retinal image from the equator to the ora serrata, 76˚ mirror provides a view of the mid-peripheral/peripheral retina Central lens provides clear view of the posterior pole Part Number: VG3 (with Flange) VG3NF (No Flange) VG3MININF (Mini, No Flange)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Viewing Anterior Chamber An all-glass design and dual mirror angles make the G-2 Gonio Lens ideal for seeing the anterior chamber in both detailed and broad views. With its superior clarity and durability, the G-2 Gonio Lens provides reliable results. This lens is available in two formats - flanged for laser trabeculoplasty and no flange for routine gonioscopy. 60° / 64°mirror angles 1.50x image magnification 0.67x laser spot size 15 mm (flange) / 8.4 mm (no flange) contact diameter High magnification combined with dual mirror angles (60°/64°) provides both a detailed and a broad view of the anterior chamber All-glass design provides superior clarity and durability Part Number: VG2 (Trabeculum Flange) and VG2NF (Trabeculum No Flange)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Viewing Trabecular Meshwork See the trabecular meshwork in unparalleled detail with the G-1 Gonio Lens. Our all-glass design gives you superior clarity and long-lasting durability, while the powerful mirror allows for highly magnified views. It’s an excellent choice for laser trabeculoplasty with our flanged format or routine gonioscopy with our no flange format. 62° mirror angle 1.50x image magnification 0.67x laser spot size 15 mm (flange) / 8.4 mm (no flange) contact diameter Requires rotation to see all quadrants of the angle Not recommended for SLT as lens does not have total internal reflection - we recommend a Volk Rapid SLT or SLT lens instead Please note: This lens is not compatible with a 532nm Nd:YAG laser (used for SLT). The intended use is for ALT procedures (Argon laser trabeculoplasty). Therefore, we do not recommend our G-1 Gonio lens for SLT - instead, we recommend a Volk Rapid SLT or SLT lens. Part Number: VG1 (with flange) / VG1NF (without flange)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Ideal for Anterior, Peripheral and Equatorial Viewing Get the same views as our G-3 Gonio lenses, but with the added benefit of a light weight, acrylic design. The 3-Mirror Lens comes uncoated for diagnostic exams and coated for use with lasers, so you have more options to suit your practice. Our advanced no fluid (ANF+) flange option only needs a coupling fluid during laser treatments. The 3-Mirror Lens is truly flexible and convenient! 60° / 66° / 76° mirror angles 0.90x image magnification 1.11x laser spot size 16 mm (no flange) / 18 mm (ANF+) contact diameter Uncoated lenses are great for diagnostic exams while coated lenses are perfect for laser treatments Not recommended for SLT - we recommend the Volk Rapid SLT or SLT lens instead Part Number: V3MIR

Phone Number

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address

Dubai - United Arab Emirates, Dubai