Hydrophilic Acrylic IOL Supplier for USA
Review hydrophilic acrylic IOL specifications with Ernest Vision. Submit model and power requirements for US ophthalmic procurement enquiries.
Hydrophilic Acrylic IOL for US Ophthalmic Procurement
Ernest Pharmaceutical Pvt. Ltd., through Ernest Vision, welcomes hydrophilic acrylic intraocular lens enquiries from US ophthalmic distributors, medical importers, eye hospitals and ambulatory surgery centres.
This page targets buyers in Miami, Philadelphia, Baltimore, Boston and Los Angeles—five cities associated with prominent ophthalmic institutions. Purchasing teams can submit their required lens model, dioptric powers and quantities for review of availability, documentation and potential supply arrangements.
Understanding the Role of an Intraocular Lens
An intraocular lens is an artificial lens used to replace the natural lens removed during cataract surgery. The National Eye Institute explains this replacement as a central part of the procedure. National Eye Institute
Relevant Latin anatomical terms include lens crystallina, meaning the natural crystalline lens, and oculus, meaning the eye. These terms provide anatomical context; procurement documents should use the manufacturer’s exact product name and model.
Technical Profile of the Specified Hydrophilic Acrylic IOL
The supplied product information describes a spherical biconvex optic with double haptics and a continuous square optic edge. Buyers should compare the following specifications with their required model before requesting an order.
| Parameter | Supplied specification |
|---|---|
| Optic diameter | 5.75 mm |
| Overall diameter | 12.00 mm |
| Optic design | Spherical biconvex |
| Haptic design | Double haptics |
| Haptic angulation | 5° |
| Optic edge design | Continuous 360° square edge |
| Refractive index | 1.4570 |
| Suggested A-constant: positive powers | 118.0 |
| Suggested A-constant: negative powers | 117.4 |
Calculation Constants for Product Reference
| Formula | Parameter | Supplied value |
|---|---|---|
| Nominal | A | 118.0 |
| Haigis | a0 | 0.568 |
| Haigis | a1 | 0.400 |
| Haigis | a2 | 0.100 |
| Hoffer Q | pACD | 4.80 |
| Holladay 1 | Surgeon factor | 1.02 |
| SRK/T | A | 117.88 |
| SRK II | A | 118.0 |
Confirm the exact lens model and applicable constants against current manufacturer documentation before clinical use.
Five US City Targets and Prominent Eye Care Institutions
The institutions below are examples of established ophthalmic centres in the selected cities. Their inclusion does not imply a customer relationship, endorsement or use of Ernest Vision products.
| Target city | Hospital or eye institute |
|---|---|
| Miami, Florida | Bascom Palmer Eye Institute, University of Miami |
| Philadelphia, Pennsylvania | Wills Eye Hospital |
| Baltimore, Maryland | Wilmer Eye Institute, Johns Hopkins Medicine |
| Boston, Massachusetts | Mass Eye and Ear |
| Los Angeles, California | UCLA Stein Eye Institute |
Ernest Vision welcomes enquiries from independent distributors, surgical facilities and hospital purchasing departments serving these locations.
Evaluate the Product Before Confirming Supply
For US procurement, the exact product identity matters. US FDA approval and eligibility for commercial supply have not been verified for the lens described here. Availability review does not establish authorisation for US sale or clinical use.
Buyers should identify their required model and request its supporting documentation before proceeding. Product photographs, catalogue references, packaging details and manufacturer information can help purchasing teams confirm that the quoted lens matches their enquiry.
Prepare a Complete Procurement Request
Send the following information for an availability and quotation review:
- Manufacturer and exact IOL model.
- Required dioptric powers and quantity for each power.
- Total order quantity and preferred delivery date.
- Delivery city and purchasing organisation.
- Required product documentation and evidence of applicable US authorisation.
- Packaging and remaining shelf-life requirements.
Quotation terms, MOQ and delivery estimates will be confirmed after reviewing the selected product and supply feasibility.
Frequently Asked Questions
1. Can US ophthalmic distributors submit bulk enquiries?
Yes. Distributors and medical importers can submit model-specific requirements for an availability review.
2. Which cities does this page target?
Miami, Philadelphia, Baltimore, Boston and Los Angeles.
3. Are the named hospitals customers of Ernest Vision?
No customer relationship is claimed. They are included as examples of prominent ophthalmic institutions.
4. Is this hydrophilic acrylic IOL FDA-approved?
Approval has not been verified for the specified model. Request model-specific evidence before considering US commercial procurement.
5. What is the lens’s optic diameter?
The supplied specification states 5.75 mm, with an overall diameter of 12.00 mm.
6. What lens powers can be ordered?
The available power range has not been confirmed. Submit your required powers for checking.
7. What does “lens crystallina” mean?
It is the Latin anatomical term for the natural crystalline lens of the eye.
8. Can product documents be requested before ordering?
Yes. Specify the datasheet, instructions for use, manufacturer details and authorisation evidence required by your purchasing team.
9. Is there a fixed minimum order quantity?
MOQ depends on the selected model, power distribution and availability.
10. Can you guarantee delivery to the USA?
Delivery arrangements can only be confirmed after reviewing the product, documentation and shipment feasibility.
Contact Ernest Vision for a Model-Specific Review