Dubai, United Arab Emirates
+919405476170
+919359902383

ophthalmic devices

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

High vapour pressure. Low surface tension and viscosity. High specific gravity. Chemically inert and free of preservative. Description Properties: Density (g/cm3): 1.78 • Kinetic viscosity at 25 °C: 0.80 • Vapour pressure (lb/in): 0.81 • Surface tension Dyn/cm: 15 • Refractive index (25 °C): 1.28

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Plastic Eye Shield with Fenestrations Single-Use Surgical Products Clear Polycarbonate OR Milky/Translucent Polypropylene OR Colored Polypropylene

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

About This Item Faster, conveninent & safer way to achive instant mydriasis Effective combination of 2 mydiatrics – Tropicamide & Phenylephirine – and a topical anesthetic Lidocaine Preservative free solution, for intracameral injection Instant dilation of pupil ( less than 30 seconds for most patients ) Long lasting dilation that subtains through time needed fo standard ophthalmic procedures Avoid cumbersome dilation through the traditional process of multiple instillation of eye drops Sterile, ready to use, prefilled syringe packing Amber coloured syringe, in a dark blister, maintains solution efficacy over long shelf life Effective answer to overcome unexpected pupil contraction during surgical procedure

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

About This Item Designed to protection ocular tissues. Ideal for Soft Shell Technique use in conjunction with a cohesive OVD Improved protection to Corneal Endothelium Prolonged retention in the eye during high flow phacoemulsification Useful for partitioning intraocular spaces into viscoelastic protected areas Premium quality, injectable grade raw material that complies to European Pharmacopeia Medium Zero-Shear Viscosity (60000-90000 m.pas at 25°C) Medium Molecular Weight (> 1.5 Million Daltons)Optically clear, dispersive fluid Sterile, pyrogen free, non-inflammatory, double filtered Synthetic fermentation – no risk of viral infections Store at ambient temperature-no need to refrigerate For ease of instillation the product is supplied In a easy peel, heat sealed blister pack With a EO Sterile packed, 27G Angular Cannula Copious 1ml volume to meet all surgical needs

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

About This Item Premium injection grade quility sodium hyluronate material Optically clear, hifhly cohesive, easy to aspoirate High Zero- Shear Viscosity ( 300,000-1,200,000 m.pas at 250 C) High Molecular Weight (> 2.8 Million Dalton ) Increased protection to corneal endothelium and ocular tissues 1ml volume in convenient pre-filled glass syringe with easy to peel blister packing Sterile, pryogen free, non-inflammatory, double filtered Synthetic fermentation – no risk of viral infections Store at room temperature – no need to refrigerate For ease of instillation the product is supplied In a easy to peel, heat-sealed blister pack with an additional colour coded syringe grip with a 27G Angular Cannul

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

About This Item A new generation Visco- Adaptive with dual behavior of cohesive & Dispersive Viscoelastic, in the same device The fluid behaves like a high viscosity cohesive mass when stationary, but behaves like a low viscosity dispersive under turbulence Ideal for high vaccum, rapid nucleus removal phaco techniques Deep chamber maintenance & easy post surgical removal due to cohesive behavior Improved protection to corneal Endothelium under turbulence, due to dispersive behavior Premium quality, injectable grade raw material that copmlies to European Pharmacopeia High Zero- Shear Viscosity ( 1,200,000 – 1,500,000 m.pas at 25o C) High Molecular Weight ( > 2.8 Million Daltons ) Optically clear, cohesive/dispersive fluid Sterile, pyrogen free, non-inflammatory, double filtered Synthetic fermentatio – no risk of viral infections Store at ambient temperature – no need to refrigerate For ease of instillation the product is supplied In a easy peel, heat sealed blister pack With a Eo sterile, blister packed, 27G Angular Cannula Copious 1ml volume to meet all surgical needs

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Occugel-Hydroxypropyl Methylcellulose Solution USP About This Item Optically Clear, Sterile, non pyrogenic Solution Premium ophthalmic grade HPMC In Balanced Salt Solution, double filtered Double pouched for Your Safety Artificial tear: It acts like natural tears to lubricate and protect the ocular surface. Moisturizing film: It forms a transparent, lubricating film on the eye to keep it moist and comfortable. Symptom relief: It provides temporary relief from dryness, irritation, burning, and discomfort. Protective agent: It is used in certain eye surgeries to protect delicate tissues and maintain hydration. Consistent Viscosity Easy to open FLIP Down Seals On Vials.

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Optima jet+ pre loading injecting system Specially designed for smoother and safer delievery of hydro phobic intraocular lens IoL Lens struck free design Easy lens unloading way Optima jet+ njector system deliever IOL from 1.80mm to 2.60mm incision with various cartridges

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Optima jet OPTIMA JET disposable injector system is specially designed for smoother and safer delivery of acrylic foldable IOL. OPTIMA JET injector system deliver the IOL from 1.8 mm to 2.8 mm incision with various cartridges Click-lock mechanism thereby securing the lens in the exact position for a perfect lens delivery into the eye. Lens insertion is gentle and without the lens wedging or twisting ensures a controlled release, and consequently a precise positioning in the eye.

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

MCS 524 SQ Optic Diameter 5.25 mm Overall Diameter 12.00 mm Optic Design Aberration Neutral, Negative Aspheric Biconvex Haptic Design “C“ Design with Step Vault PCO Protection 360˚ perfect Square edge around the optic edge Suggested A. Constant 118.4 Refractive Index 1.4915 Nominal A 118.4 Haigis a0 0.779 Haigis a1 0.400 Haigis a2 0.100 HofferQ pACD 5.01 Holl. 1 Const sf 1.23 SRK/T A 118.2 SRK II A 118.4 MCS 553SQ Optic Diameter 5.50 mm Overall Diameter 12.50 mm Optic Design Aberration Neutral, Negative Aspheric Biconvex Haptic Design “C“ Design with Step Vault PCO Protection 360˚ perfect Square edge around the optic edge Suggested A. Constant 118.4 Refractive Index 1.4915 Nominal A 118.4 Haigis a0 0.779 Haigis a1 0.400 Haigis a2 0.100 HofferQ pACD 5.01 Holl. 1 Const sf 1.23 SRK/T A 118.2 SRK II A 118.4 MCS 603SQ Optic Diameter 6.00 mm Overall Diameter 12.50 mm Optic Design Aberration Neutral, Negative Aspheric Biconvex with 2 Holes Haptic Design “C“ Design with Step Vault PCO Protection 360˚ perfect Square edge around the optic edge Suggested A. Constant 118.4 Refractive Index 1.4915 Nominal A 118.2 Haigis a0 0.673 Haigis a1 0.400 Haigis a2 0.100 HofferQ pACD 4.91 Holl. 1 Const sf 1.12 SRK/T A 118.04 SRK II A 118.2

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

VAF 6520 Optic Size 6.50mm Overall Length 12.00 mm Haptic Angulation 0° Haptic Design one piece lens 360° Square Edge Technology Material 26% hydrophilic Acrylic UV Filter yes Sterilization Method Steam Diopter +41 D Package Sterile Under Blister AC Depth 5.0 mm A Constant 118.0 VAF 6530 Optic Size 6.50mm Overall Length 13.00 mm Haptic Angulation 0° Haptic Design one piece lens 360° Square Edge Technology Material 26% hydrophilic Acrylic UV Filter yes Sterilization Method Steam Diopter +41 D Package Sterile Under Blister AC Depth 5.0 mm A Constant 118.0 VAF 6540 Optic Size 6.50mm Overall Length 14.00 mm Haptic Angulation 0° Haptic Design one piece lens 360° Square Edge Technology Material 26% hydrophilic Acrylic UV Filter yes Sterilization Method Steam Diopter +41 D Package Sterile Under Blister AC Depth 5.0 mm A Constant 118.0

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Model Name Optima Binary Tri EF Model Number TRI-FO-617 Power range 0.0 D to +30.0 D (increments 0.5 D) Trifocal, diffractive, +3.5 D near add and +1.75 D intermediate add at the IOL plane Delivery System Biconvex, Anterior Toric Aspheric Surface Injector Type Preloaded IOl / Non preloaded injection system / Click Lock Mechanism for smoother Delivery Incision Size 2.20 mm nozzle for sub 2.4 mm incision Bevel Angle 45° Lens Delivery Single handed plunger Aspheric Trifocal IOL 2.6 mm Material Single Piece Hydrophobic / Hyrophilic Acrylic Water Content 0.5% Hydrophobic / 26% Hydrophilic Refractive Index Hydrophobic - 1.4933 / Hydrophilic - 1.555 Overall Diameter Hydrophobic - 12.50 mm & 13.00 mm / Hydrophilic 10.60 mm Optic Diameter 6.00 mm Optic Shape Biconvex Aspheric Asphericity Aberration - neutral technology Optic Edge Design 360° enhanced square edge Haptic Angulation 0° Haptic Style: Hydrophobic - C Loop / Hydrophilic - Plate Haptics Suggested A constant Hydrophobic A constant UltraSound Optical Biometry Nominal A 118.1 119.1 Haigis a0 1.34 1.96 Haigis a1 0.400 0.400 Haigis a2 0.100 0.100 HofferQ pACD 5.02 5.61 Holl. 1 Const sf 1.28 1.85 SRK/T A 117.8 118.8 SRK II A 118.1 119.1

Phone Number

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Dubai, United Arab Emirates

Dubai, United Arab Emirates, United Arab Emirates, 25314