Dubai, United Arab Emirates
+919359902383
+919359902383

Items tagged with 'intraocular pressure measurement device'

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

A modern approach to diurnal IOP monitoring The iCare HOME2 tonometer for patient use revolutionizes glaucoma care. The patient can take IOP measurements during normal daily activities throughout the day and the iCare HOME2 can even be used when the patient is lying down. Measurement results are uploaded to a cloud database from where they are easily accessible both to the doctor and the patient. The doctor is provided with accurate real world IOP data to support treatment decisions. Key features Reliable and accurate Easy to deploy and use Informative user interface Measurements also in supine position A new mobile app with IOP graphs for patient use Private cloud account for patient use Instant data transfer to the clinic iCare HOME2 tonometer Type TA023 Dimensions (WxHxL) 50 mm x 94 mm x 152 mm (supports extended to maximum) 2.0” x 3.7” x 6.0” (supports extended to maximum) Weight 205 g (without batteries) / 0.45 lbs (without batteries) 300 g (with 4 x AA batteries) / 0.66 lbs (with 4 x AA batteries) Power Supply 4 x 1.5 V, AA, non-rechargeable batteries, alkaline LR6 Measurement range 7 – 50 mmHg Accuracy ±1.2 mmHg (≤ 20 mmHg) and ±2.2 mmHg (> 20 mmHg) Repeatability (coefficient of variation) < 8 % Precision of display 1 mmHg Display unit millimeters of mercury (mmHg) Bluetooth module RN4678 Bluetooth 4.2 Dual Mode Enhanced ease of use with iCare HOME2 and PATIENT2 The iCare HOME2 monitoring is easy to deploy as most patients can use the device with the help of intuitive training materials. iCare HOME2 guides the patient to take high quality measurements every time. As with all iCare tonometers, measuring requires no anesthesia, drops, air or other preparation. Many clinical studies have shown iCare HOME, the predecessor of iCare HOME2, to be accurate and reliable. With the intuitive PATIENT2 mobile app, the patient can follow his or her IOP trends in an iOS or Android mobile device and easily send the IOP results for healthcare professional’s review. Glaucoma treatment decisions supported by comprehensive and reliable IOP data iCare HOME2 allows measurements at different times of the day over several days providing a comprehensive picture of IOP fluctuations. At-home measurements may help reveal IOP spikes that would not have been identified had measurements only been taken during office hours, in the clinic. Doctors have access to the results at any time and the system can be configured to send the doctor an e-mail alert if the IOP rises above a pre-set limit. The relationship between intraocular pressure and glaucoma: An evolving concept Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Benefits of using iCare HOME2 Helps to compare the effect of various medications on IOP to find the optimum regime for a specific patient. The IOP data can reveal the need for surgery sooner. iCare’s measurement technique allows post-surgical monitoring to begin without delay. Can be instrumental when treating patients with progressing glaucoma despite reasonable IOPs at the clinic. Through enabling patients to collect IOP data and clinicians to follow up with them remotely, iCare HOME2 can save patients’ time and healthcare resources. The ability to deliver virtual care is valuable in rural and remote settings. Patients actively contributing to glaucoma care Glaucoma suspects and patients can measure their IOP using the HOME2 tonometer during normal activities as directed by their doctor. The iCare PATIENT2 mobile app provides the patient a graphical view of their IOP measurements history which can increase compliance with their treatment plan and follow up appointments. The IOP measurement results are easily shared with the doctor. Connecting patients and healthcare professionals iCare CLINIC is a cloud-based software available for practices and hospitals for storing and analyzing IOP information. The IOP information is easily accessible using a mobile app or a web browser and is available for physicians and patients 24 hours a day, seven days a week. Informative reports are available including a report that compares IOP measurement results from before and after a medication change or a pressure lowering procedure. Uploading IOP information from the iCare tonometers to the cloud happens easily with the iCare PATIENT2 app using a mobile device or with the iCare EXPORT software running in a PC environment.

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

TONOVUE Automatic Non-Contact Tonometer is an advanced air-puff tonometer designed for fast, accurate, and patient-friendly intraocular pressure (IOP) measurement. Supplied worldwide by @ErnestVision, a specialized ophthalmic equipment exporter from India, TONOVUE is widely used in eye clinics, hospitals, optometry centers, and screening camps for reliable glaucoma assessment. TONOVUE Automatic Non-Contact Tonometer Supplier in Washington, D.C. TONOVUE Automatic Non-Contact Tonometer Supplier in London, UK TONOVUE Automatic Non-Contact Tonometer Supplier in Riyadh, Saudi Arabia TONOVUE Automatic Non-Contact Tonometer Supplier in Bangkok, Thailand TONOVUE Automatic Non-Contact Tonometer Supplier in Canberra, Australia TONOVUE Automatic Non-Contact Tonometer Supplier in Singapore TONOVUE Automatic Non-Contact Tonometer Supplier in Kingston, Jamaica 🔬 Product Overview – TONOVUE Automatic Non-Contact Tonometer Device Type: Automatic Non-Contact (Air Puff) Tonometer Function: Intraocular Pressure (IOP) measurement Applications: Glaucoma screening, routine eye exams Patient Comfort: Contactless & anesthesia-free testing Users: Ophthalmologists, optometrists, eye clinics Supply: New equipment with export-ready support ⚠️ For professional ophthalmic and optometry use only. 📦 Why Choose @ErnestVision Specialized ophthalmic equipment exporter from India Trusted by hospitals, eye clinics & distributors globally Complete technical manuals, certifications & export support Worldwide logistics via DHL, FedEx, Aramex Dedicated pre-sales & after-sales coordination 📞 Contact – ErnestVision @ErnestVision | @ErnestImpex 🌐 www.ernestvision.com | www.ernestimpex.com 📧 exports@ernestpharmaceuticals.com 📲 WhatsApp: +91 93599 02383 🔗 https://wa.me/919359902383

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Soft and gentle air puff technology Our Keeler Pulsair IntelliPuff combines the best of electronic and optical technology to deliver the speed, accuracy and comfort that you and your patients deserve. Versatile, easy-to-use and featuring an intelligent puff system, enabling you to measure intraocular pressure without contacting the eye, the Pulsair IntelliPuff will quickly become a favoured companion for your glaucoma screening and diagnosis. Benefits: Hand-held – for patient convenience and ease of use Lighter puff – soft and gentle for your patients Greater accuracy – uses algorithms to ensure best readings Space saving flexibility – can be wall or desk mounted Sustainable cost savings – no need for sterile consumables Easy to use – time on target system Designed, engineered and hand-assembled in the UK SKU: 2414-P-2001 Usage overview The Keeler Pulsair IntelliPuff is a portable screening device used to measure intraocular pressure which is one of the key biomarkers considered in diagnosing glaucoma. Electrically powered and handheld, the system provides the user with a position detection display to aid alignment of the tonometer relative to the eye. Once the system is aligned, the Pulsair IntelliPuff will automatically take IOP measurements. The system also allows the user to print IOP measurements taken of both eyes. Our softest puff ever Gentle is an understatement. If the patient has high pressures the puff will automatically increase for the next measurement. Kind, intelligent and simple. Technology working for you. Save valuable space Pulsair IntelliPuff uses less than 50% of the space of conventional non contact tonometers and is the only model that can be wall mounted. Whether you wall mount or prefer to place it on your desk you win the ‘space war’ every time. No special instrument table is required – put it where you want it. Move it when you want to. Convenient and easy to use Being hand held, the Pulsair IntelliPuff removes the need to position the patient in a chinrest, enhancing the patient journey and making it quick and easy for you to screen while the patient is seated in an examination chair. Contents: Pulsair IntelliPuff Power Supply Unit Pulsair IntelliPuff Dust Cover USB Instruction Manual IntelliPuff wall mounting kit Thermal printer roll Tonometer face shield Instructions CD

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

G-Matronix ABS Echo San-A-AP Function Specification Material ABS Technology Digital Usage Hospital G-Matronix ABS Echo San-A-AP Function Trade Information Minimum Order Quantity 1 Piece Supply Ability 2 Pieces Per Day Delivery Time 15 Days Main Domestic Market All India About G-Matronix ABS Echo San-A-AP Function By keeping track with the market development, we are offering optimum quality Echo San-A-AP Function. Our provided device is manufactured by a team of our adept professionals utilizing quality approved raw material and advanced technology. Our offered device is widely appreciated by our prestigious clients for its precise design and durability. The offered device can also be availed in various sizes, designs and other related specifications. Features: Show actual value and deviation at the same time Sensitive, convenient, accurate and fast measurement The Probe service life is long, better cost performance Point and surface point measurement display Cabinet and delicate foot switch, convenient operation Calculate the calibration value of intraocular pressure (after achieving accurate intraocular pressure) Ultrasonic velocity and offset is adjustable compare measuring results with other equipment easily. 5.7šž color LCD touch screen, and user information can be easily input, more convenient and quick.

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Reliability and ease of use Discover the added reassurance of a digital Keeler Applanation Tonometer (D-KAT); a Goldmann tonometer with the potential for human error removed. As a measurement device for tower illumination Z-style of slit lamp, the D-KAT (Z-Style) is equipped with an LED display and internal electronics to guarantee fast and accurate measurements. Benefits: Designed for Z-style tower illumination slit lamp Reliable diagnosis to 1 decimal point LED display – for ease of use in darkened environments Low battery usage Designed, engineered, and handmade in the UK Our digital GAT range uses the Goldmann method of measuring intraocular pressure (IOP), which is to calculate the force required to flatten (applanate) a constant area (3.06mm) of the cornea to aide in the diagnosis of glaucoma. Keeler digital applanation tonometers (D-KATs) are a versatile measurement device for a wide variety of lower and tower illumination slit lamps. Usage overview The Digital Z-KAT is a screening device used to measure intraocular pressure which is one of the key biomarkers considered in diagnosing glaucoma. It is intended to be used by suitably trained and authorised healthcare professionals only. Please note that the Z-KAT is specifically designed to fit onto Z-style slit lamps only. Contents: D-KAT (Z-Type) Calibration arm assembly D-KAT (Z-Type) mounting bracket assembly Reusable tonometer prism AA battery Instructions for use (IFU)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Exceptional versatility The Keeler TonoCare 2.0 has been designed and built with the comfort of both patient and clinician in mind. Lightweight, yet robust, and simple to use within all types of environment, it consistently gives fast and accurate readings you can rely on. Benefits: Accuracy and consistency – advanced optical and sensor technology User friendly – intuitive controls and ‘head up’ display for ease of reading Patient comfort and reassurance – adjust the headset or offer reassurance, right when they need it Sustainable cost savings – no need for sterile consumables Multi-functional docking station – for charging, practicing and printing results! Designed, engineered, and hand-assembled in the UK According to WHO, glaucoma is the second leading cause of blindness globally. As a leader in the field of tonometry, we’re passionate about playing a pivotal role in its detection, by producing reliable, high quality products which are affordable too. Designed with consideration for all the different environments clinicians face around the world, the TonoCare 2.0 has a long-lasting battery, compact design and is fully portable. This means that however mobile your patient or whatever environment you’re in, you’re guaranteed a consistent performance time and time again. Usage overview The Keeler TonoCare 2.0 is a screening device used for measuring intraocular pressure which is one of the key biomarkers considered in diagnosing glaucoma. The TonoCare 2.0 has a unique converging nozzle design more commonly seen in jet engines, to deliver a puff of air to the exact location on the eye. Teamed with a quick and effective positioning system, reliable measurements can be taken in seconds. Accuracy and consistency The TonoCare 2.0 uses advanced optical and sensor technology for position detection and puff control. It has been rigorously tested and compared closely to GAT; with accurate, consistent measurements, enabling you to monitor changes in IOP over time with complete confidence. User friendly The intuitive ‘head up’ display enables you to be in the right position every time to take and record an accurate measurement. Plus, easy to follow instructions and intuitive controls mean user training can take just minutes. Patient comfort and confidence Fitted with an adjustable headrest, this highly portable unit allows you to take measurements wherever your patient is most comfortable. Plus, the sleek profile allows you to maintain visual contact at all times, in order to provide patient reassurance as required Patient safety Using non contact ‘air puff; technology eliminates any risk of eye damage or cross contamination between eyes. Multi-functional docking station The TonoCare 2.0 comes with its own dedicated charger stand with built in printer, which can be desk or wall mounted. The power connector is interchangeable and can be connected to the hand unit directly or plugged into the docking station so the unit charges automatically when docked. The docking station also features a ‘test eye’, for operator practice. Contents: TonCare unit Docking station Adjustable headrest Power supply kit USB cable USB PC cable Instruction USB Rubber eyepiece Wall mount kit TonoCare carry case Tonometer face shield Printer paper roll (1 pack)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

Reliability and ease of use Discover the added reassurance of a digital Keeler Applanation Tonometer (D-KAT); a Goldmann tonometer which operates according to the 'Goldmann method', by measuring intraocular pressure from the force required to flatten (applanate) a constant area (3.06mm) of the cornea. As a measurement device for tower illumination Z-style of slit lamp, the D-KAT (Z-Style) is equipped with an LED display and internal electronics to guarantee fast and accurate measurements. Benefits Reliable diagnosis to 1 decimal point LED display - for ease of use in darkened environments Low battery usage Designed, engineered and handmade in the UK Our digital GAT range uses the Goldmann method of measuring intraocular pressure (IOP), which is to calculate the force required to flatten (applanate) a constant area (3.06mm) of the cornea to aide in the diagnosis of glaucoma. Keeler digital applanation tonometers (D-KATs) are a versatile measurement device for a wide variety of lower and tower illumination slit lamps. Usage overview The Digital Z-KAT is a screening device used to measure intraocular pressure which is one of the key biomarkers considered in diagnosing glaucoma. It is intended to be used by suitably trained and authorised healthcare professionals only. Please note that the Z-KAT is specifically designed to fit onto Z-style slit lamps only. What's in the box? D-KAT (Z-Type) Calibration arm assembly D-KAT (Z-Type) mounting bracket assembly Reusable tonometer prism AA battery Instructions for use (IFU)

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

iCare IC200 tonometer with 200 degrees positional freedom iCare IC200 is the most versatile tonometer in iCare’s product portfolio. This flagship device is designed for professional use in the clinic as well as in eye surgery and emergency rooms. With 200 degrees of positional freedom, it can measure intraocular pressure (IOP) whether the patient is standing, sitting, elevated or in a supine position. Key features 200-degree position freedom Quick Measure for easier and faster IOP measurements Suitable for all patients Consistent and accurate readings No anesthetic drops Improved probe control No calibration Extensive flexibility in positioning is especially useful in clinical, surgical or emergency settings when the patient’s eye pressure needs to be measured regardless of the patient’s position. Freedom to measure in multiple positions The most crucial development in IC200 compared to other iCare’s tonometer's is its freedom in the measurement position. The patient can stand, sit, be in an upright, supine or lateral recumbent position. The tonometer IC200 can be used in 200 degrees measurement angle. As with other iCare tonometer's, the professional iCare IC200 tonometer is based on a rebound measuring principle that requires no anesthetic drops, air or specialized skills for its use. Experience faster and easier IOP Measurements with the Quick Measure feature Quick Measure is an innovative upgrade to the iCare IC200 that offers all the benefits of iCare’s patented rebound technology but in a faster and more optimized manner. The new feature enables the iCare IC200 to measure IOP using only two or three rapid individual measurements instead of the standard six. This reduces test time to about one-third of the device’s default measurement method, making Quick Measure an ideal solution for even the most challenging patients. Read more about the unique Quick Measure feature and how it can enhance the tonometry experience. Five reasons to always choose original iCare probes for iCare tonometer's The probes are integral to accurate functioning of iCare tonometer's and they are designed to ensure that every IOP measurement is accurate and safe. Read the five reasons why it's important to always use the original iCare probes with our tonometer's. Reliable, repeatable measurements An intuitive user interface maximizes clinical efficiency even in the most demanding situations. Display and navigation buttons are on the backside of the device towards the user. With iCare IC200 IOP measuring is fast, accurate and reliably repeatable, with individual readings displayed to one-decimal mmHg resolution. Compared to other iCare tonometer's, the iCare IC200 tonometer accepts only measurements which are taken in the correct way - perpendicularly from the center of the cornea. This new position technology makes the results even more reliable and accurate. Wireless printing and data transfer via Bluetooth The tonometer can be paired with a Bluetooth printer for printing the measurement results or with a computer for transferring the measurement results. To export the measurement results you first need to pair the IC200 with the computer having Bluetooth Low Energy (BLE) functionality and iCare EXPORT Software installed.

6814772a5d263414004dd4a4 Card 2

product image
Ophthalmic Devices

iCare IC100 tonometer for all eye care professionals iCare IC100 is a reliable choice for all eye care professionals. With this tonometer, you can measure the intraocular pressure of patients in a sitting or standing position. Optometrists and ophthalmologists have successfully used IC100 for routine IOP measurement and glaucoma screenings, as measuring has never been more accessible – just load, align and measure. Ideal for use anywhere Fully portable iCare IC100 makes it possible to measure the IOP of your patients wherever they are. The results are always reliable. Easy to use with minimal training iCare IC100 is proven to be easy to use by numerous physicians and staff all over the world. The use of the tonometer requires only minimal training. User-friendly display of results and language selection The iCare IC100 tonometer incorporates an intuitive user interface to navigate from measurement mode to history. Multiple languages are available for your convenience. Five reasons to always choose original iCare probes for iCare tonometers The probes are integral to accurate functioning of iCare tonometers and they are designed to ensure that every IOP measurement is accurate and safe. Read the five reasons why it's important to always use the original iCare probes with our tonometer's. iCare IC100 for all eye care professionals iCare IC100 is a modern tonometer that meets the needs of ophthalmologists and optometrists in different medical institutions from small and large clinics to hospitals to optical shops. The tonometer is suitable for any, even your youngest or otherwise non-compliant patients. All iCare’s tonometers, including the iCare IC100, use patented rebound technology, which allows painless and hygienic IOP measurement without local anesthetic. iCare IC100 is also an ideal tool for screening. Since increased IOP is a known risk factor for glaucoma, you will appreciate how quick and effortless the measuring is with IC100. The measuring is fast as there is no need for anesthetic drops or other preparation. This device allows you to take single or rapid 6-series measurement with one button. iCare IC100 tonometer also has an advanced positioning assistant for correct alignment. The red or green light of a probe base indicates correct or incorrect positioning of the device. iCare IC100 tonometer - the professional's choice Key features Suitable for all patients Fast to measure Easy to use Automated Measurement Sequence Consistent and repeatable No anesthetic drops, air or calibration needed iCare IC100 Tonometer Model name TA011 Dimensions 24-29 mm x 35-95 mm x 215 mm Weight 140 g (without batteries), 230 g (4 x AA batteries) Batteries 4 x AA non-rechargeable batteries, 1.5V alkaline LR6 Measurement range 7 - 50 mmHg Accuracy (95 % tolerance interval relative to manometry): ±1.2 mmHg (20 mmHg) and ±2.2 mmHg (>20 mmHg) Repeatability (coefficient of variation) <8%

Still searching for
intraocular pressure measurement device?